You didn't already do that, did you? There are two cardinal rules for the care and feeding of the RSCommon folder and the EDS registration mechanism. Rule 1: Never copy or move an EDS file directly to the RSCommon/EDS folder. Rule 2: If you violate Rule 1, never run the EDS Wizard or Registration Tool on a file that is already located in the RSCommon/EDS folder. CompactLogix actually needs several EDS files; the controller, the comms daughtercard, and the virtual backplane. I think they're all bundled together these days.

Whenever I need an EDS file I get all of them that could possibly be the one I would need and download and register them. Harddrive space is cheap and the time spent going back and forth to figure out the right one is not worth it. I wish AB would make some of their new equipment so that it would store its EDS file in the memory of the device and RSLinx would upload if it needed it. If you load new firmware in something part of the download process could replace the EDS file with a new one. This would save a lot of time and make a lot of people happy.

It really blows to show up somewhere and go to connect to equipment and find out the new stuff has a new revision of firmware, but your out at a lift station/water tower, etc. That is im the middle of nowhere.

Now the rest of your day is spent trying to find an internet connection and then trying to figure out which EDS file to download. I'm with jtn. When I get EDS files I download and install every available version unless I know I already have a specific one. If you want to find out what you have installed you can open the EDS install tool and select 'Remove'. The first thing the tool does is take an audit of the registered EDS files. You can use this to see what you have registered.

Just cancel the process and you won't delete anything. My big beef with Linx is that it is so restrictive. I find it hard to believe that the data access mechanism of a ControlLogix processor has changed so much from version to version that Linx can't access it without the correct version EDS. The same goes for the ENBT or CNB cards. I can see why there should be some indication that you don't have the correct version. But why wouldn't Linx just give the connection the old college try using the EDS file from a previous version?

Let the user decide if it's wrong. It's not a cure-all, but the good news is that many new products have the EDS embedded in them. Take a look at the default web page for a 1734-AENT, for example, and you will find a link to the EDS file that can be downloaded directly from the device.

Many DeviceNet products, too, support the 'upload EDS' wizard function because they contain a full Parameter object that RSNetworx can build an EDS from. Anyhow, to the matter at hand with the PV+.

Feb 03, 2003 23893 Using the EDS Hardware Installation Toolhttps. In Windows click Start=>Rockwell Software=>RSLinx Tools=>EDS Hardware Installation Tool. EDS files and eliminate yellow question. EDS Hardware Installation Tool which is installed by default when you install RSLinx Classic: Step 7) Once the tool.

There are three drivers that can 'see' a PV+ terminal on Ethernet; the RSLinx Classic 'Ethernet Devices' driver and EtherNet/IP drivers, as well as the RSLinx Enterprise EtherNet/IP driver. If it's one of the EtherNet/IP drivers and it shows a question mark, then we probably have an identity problem related to EDS registration. Bharatha matha. I have also seen some instances where the user purposely or inadvertently deleted the Ethernet driver in the Target tab of the RSLinx Enterprise configuration.

That meant that when the.MER runtime file got loaded onto the PV+ terminal, it replaced the current RSLinx Enterprise configuration with one that lacked an Ethernet driver. Even though Windows CE handles the IP address and basic TCP/IP functions for the PV+ terminal (which is why it will respond to PING), RSLinx Enterprie handles all the Rockwell-related services, including providing identity and services to other computers' RSLinx browsers. If the PV+ has no Ethernet driver, it will not respond to EtherNet/IP 'List Identity' commands, which is what the PC's RSLinx Enterprise and Classic EtherNet/IP drivers use to discover Rockwell products on a network. So; check which driver you're using to 'see' the PV+, and check in the online Application Settings to see if there is an Ethernet driver configured.

It's not a cure-all, but the good news is that many new products have the EDS embedded in them. Take a look at the default web page for a 1734-AENT, for example, and you will find a link to the EDS file that can be downloaded directly from the device. Many DeviceNet products, too, support the 'upload EDS' wizard function because they contain a full Parameter object that RSNetworx can build an EDS from. That's good news, it's been a while since I did devicenet so I guess I hadn't noticed. When I upgraded to ControlLogix V15 I don't remember having EDS issues with the ENET or CNB cards. The PowerFlex drives give me some ControlNet EDS issues, but it got worked through somewhat quickly.

The main problem there was the P/N's for the drives didn't show up on the EDS page and no one at tech support could tell me what EDS file to use. Just to clarify the exact issue, I know it's hard to come up with solutions when you don't know everything possible about the problem. The Linx Enterprise driver recognized the PV+ without a problem.

The RSLinx Classic driver sees a panelview, but gives questionmark and device not recognized. I have configured an Ethernet devices driver. Tomorrow I will try the Ethernet IP driver and see if that makes any difference. One thing to note, I have PV+700s that are configured as Ethernet devices drivers, and Linx recognizes those without a problem.

This is the real reason for my question. I ran all the EDS files at the same time for the PV+'s, from the 600 all the way to 1500. So far, upgrading to Linx 2.5 has made no difference. AB tech support said to try that, and to try the IP driver. I will post my results tomorrow. Thanks for all the input.

Hi to everyone, I am having a problem establishing a communication between a PanelView Plus Compact with a 1769-L33ER controller. I have already downloaded the EDS file for my revision (20) and my RSLinx can see the chassis controller (CPU and all the other cards) When I open the communication setup for RSLinx Enterprise on FTView Studio I start to look the Chassis but it has a question mark.

I open the whole tree and I can see all the cards except a 1769-OF4Cl that has also a question mark. I have downloaded many EDS files for the controller but I am not sure what does the problem can be. Thanks in advance.

Hardware

OVERVIEW A buffer overflow vulnerability exists in the Rockwell Automation RSLinx Classic EDS Hardware Installation Tool (RSHWare.exe). This vulnerability is likely exploitable; however, significant user interaction would be required. AFFECTED PRODUCTS EDS Hardware Installation Tool Version 1.0.5.1 and earlier. IMPACT The CVSS impact subscore for this vulnerability, as calculated by ICS-CERT, is high (10) because successfully exploiting this vulnerability would allow an attacker to run arbitrary code on the target machine.

However, the exploitability subscore is low (3.2) because of the difficulty of exploiting this vulnerability. Impact to individual organizations depends on many factors that are unique to each organization.

ICS-CERT recommends that organizations evaluate the impact of this vulnerability based on their environment, architecture, and product implementation. BACKGROUND Rockwell Automation provides industrial automation control and information products worldwide across a wide range of industries. RSLinx provides connectivity to plant floor devices for Rockwell software applications. To register a device on the network, product specific information must be supplied via an Electronic Data Sheet (EDS) file. The RSLinx Hardware Installation Tool parses the EDS file containing the hardware’s specifications.

VULNERABILITY CHARACATERIZATION VULNERABILITY OVERVIEW. On February 9, 2010, a security researcher posted a blog entry regarding a buffer overflow vulnerability in an EDS file installation tool, later found to be the Rockwell Automation EDS Hardware Installation Tool (RSHWare.exe). ICS-CERT has verified that the vulnerability exists in RSLinx Classic Version 2.41.00 (RSHWare.exe Version 1.0.4.0).

VULNERABILITY DETAILS Common Vulnerability Scoring System (CVSS) Score Overall CVSS Score: 6.2. CVSS Base Score: 6.9. Impact Subscore: 10. Exploitability Subscore: 3.4. CVSS Temporal Score: 6.2.

CVSS Environmental Score: Organization Defined Shorthand CVSS Scoring Notation: AV:L/AC:M/Au:N/C:C/I:C/A:C/E:POC/RL:U/RC:C EXPLOITABILITY This vulnerability is likely exploitable; however, it is not possible without user interaction. An attacker cannot initiate the exploit from a remote machine. The exploit is only triggered when a local user runs the vulnerable application and loads the malformed EDS file. EXISTENCE OF EXPLOIT There are currently no known exploits specifically targeting this vulnerability.

DIFFICULTY Crafting a working exploit for this vulnerability would be difficult. Social engineering is required to convince the user to accept the malformed EDS file. Additional user interaction is needed to load the malformed file. This decreases the likelihood of a successful exploit. MITIGATION recommends customers take the following steps to mitigate risk associated with this vulnerability:. Restrict physical access to the computer.

Establish policies and procedures such that only authorized individuals have administrative rights on the computer. Obtain product EDS files from trusted sources (e.g., product vendor).

Ed's Hardware Naugatuck Ct

Rockwell Automation will modify the EDS Hardware Installation Tool to properly handle EDS files and will release the modified version as a patch by May 2010. This modified version will be included in all future releases of RSLinx Classic starting with Version 2.57. BEGIN UPDATE A. Rockwell Automation has issued a software patch for the EDS Hardware Installation Tool that addresses this buffer overflow vulnerability.

When applied, the patch replaces the RSEds.dll file with the modified Version 4.0.1.157. Future releases of RSLinx Classic, starting with Version 2.57, will include this modified version of the RSEds.dll. Rockwell has also updated Technote to include instructions for how to obtain and apply the patch.

END UPDATE A. In addition, ICS-CERT recommends that users take the following measures to protect themselves from social engineering attacks:.

Rslinx Eds Hardware Installation Tool

Do not click web links or open unsolicited attachments in e-mail messages. Refer to for more information on avoiding e-mail scams. Refer to for more information on social engineering attacks. The Control System Security Program also provides a recommended practices section for control systems on the US-CERT website.

Several recommended practices are available for reading or download, including. Contact Information For any questions related to this report, please contact the NCCIC at: Email: Toll Free: 1-888-282-0870 For industrial control systems cybersecurity information: or incident reporting: The NCCIC continuously strives to improve its products and services.

You can help by choosing one of the links below to provide feedback about this product.