Look at most relevant Cacti template windows 2008 websites out of 73.1 Thousand at KeyOptimize.com. Cacti template windows 2008 found. Today I am going to go through a quickinstallation of these templates into a new cacti. Cacti Monitoring for Windows. Then add a windows server 2008.

کد: So you have a new Windows Server 2008 R2 installed and now you’d like to start gathering statistics about how it’s performing. The SNMP protocol is a great way to get started. In this tutorial I will install the SNMP agent service on a Windows server and configure it to allow queries from a SNMP based management server. On the management server I will use a tool named Cacti that can collect this SNMP information and generate graphs from it in a fairly easy way.

Download free software Cacti Templates Windows 2008. Monitoring Windows Server 2008 R2 with SNMP and Cacti. June 2, 2010 awalrath Leave a comment Go to.

I will assume that you have a server with Cacti already set up. If not, details on how to set up an instance of Cacti on a CentOS Linux server can be found فقط اعضا می توانند لینک ها را مشاهده کنند. Install and Configure Windows SNMP Agent Okay first of all let’s install the Windows SNMP agent service.

Start Server Manager. فقط اعضا می توانند لینک ها را مشاهده کنند Scroll down to the Features Summary section and click Add Features. فقط اعضا می توانند لینک ها را مشاهده کنند Under Features open up SNMP Services and check SNMP Service. فقط اعضا می توانند لینک ها را مشاهده کنند Click Install at the confirmation screen, then click Close when the install is complete. فقط اعضا می توانند لینک ها را مشاهده کنند Now it is time to configure the SNMP Service. Back in the Server Manager in the left pane open up Configuration and select Services. In the middle Services pane scroll down and double click the SNMP Service.

فقط اعضا می توانند لینک ها را مشاهده کنند Click the Agent tab and enter your Contact and Location information. فقط اعضا می توانند لینک ها را مشاهده کنند For now we’ll skip any configuration in the Traps tab. This should only be necessary if you want to configure the SNMP agent to notify our monitoring server of any events without the monitor soliciting the information. In the Security tab under Accepted Community Names click Add. فقط اعضا می توانند لینک ها را مشاهده کنند We’ll only be reading information (and not setting parameters) on the SNMP agent so keep Read Only and type a Community Name. Using a name other than “public” will help keep unauthorized clients from reading SNMP information from the agent but this is still not completely secure. فقط اعضا می توانند لینک ها را مشاهده کنند Now click the second Add button under Accept SNMP Packets.

فقط اعضا می توانند لینک ها را مشاهده کنند Type the IP address or hostname of the Cacti management server and click Add. فقط اعضا می توانند لینک ها را مشاهده کنند Make sure that “Accept SNMP packets from these hosts” is still selected, then click OK Configure Cacti Server Now we need to configure our Cacti server. Type فقط اعضا می توانند لینک ها را مشاهده کنند into your web browser and login. فقط اعضا می توانند لینک ها را مشاهده کنند On the left side under the Management section click Devices. فقط اعضا می توانند لینک ها را مشاهده کنند Now in the center look for the Devices heading in blue and click Add way over on the right side. فقط اعضا می توانند لینک ها را مشاهده کنند Enter a Description and Hostname/IP Address for your Windows server.

Under Host Template select Windows 2000/XP. There is an updated Windows Vista/2008 template available in the Cacti forums which has more functions available. Under SNMP Version choose Version 2.

Also in the SNMP Community field type in the community that you configured on the SNMP agent. Click Create. فقط اعضا می توانند لینک ها را مشاهده کنند The screen should notify us at the top if the save was successful. Cacti will display some of the SNMP information the Windows agent has configured like the Windows Version and the Contact info that we entered before. On the right click “Create Graphs for this Host”. فقط اعضا می توانند لینک ها را مشاهده کنند Make sure that the correct host is displayed and under Graph Templates select a graph type that you want to create.

I’ll choose Host MIB – Processes to display the number of processes running on my server. Not massively interesting, but something to get us started.

W8snmp2

Click Create. فقط اعضا می توانند لینک ها را مشاهده کنند We can choose an alternate color for the processes parameter if we desire. Click Create.

فقط اعضا می توانند لینک ها را مشاهده کنند At the top in small letters it should display that the graph was created. Now click Devices again on the left to go back to the device list. فقط اعضا می توانند لینک ها را مشاهده کنند Cacti should update the status of our Windows server as being “Up”. It may take a little while for the status to update so you may need to go back and click Device on the left periodically. I have noticed that devices appear to need to have a graph associated with them (as we did above) in order for the Up status to be achieved. On the left click Graph Trees. فقط اعضا می توانند لینک ها را مشاهده کنند Way on the right side click Add across from the Graph Trees heading in blue.

فقط اعضا می توانند لینک ها را مشاهده کنند We’ll place the host’s graphs under a host branch of the default tree. Across from Tree Items on the right click Add. فقط اعضا می توانند لینک ها را مشاهده کنند For the Tree Item Type select Host. Then for the Host field make sure the correct system is listed.

Graph Grouping Style should have Graph Template listed. Click Create. Now click the Graphs tab at the top. فقط اعضا می توانند لینک ها را مشاهده کنند Our new host should now appear under the Default Tree on the left.

W8snmp8

Windows 2008 r2 upgrade

Click the new host on the left. فقط اعضا می توانند لینک ها را مشاهده کنند If all goes well you’ll see a graph with the number of processes running on the Windows server. Not a very exciting graph but hopefully it has wet your appetite for more. If you’d like to add more graphs be sure and click the Console tab and go back into the Device list.

Except for the 30 second polling, this is pretty standard. Read the manuals here:.

Using Cacti How do I create traffic graphs? snip Now that you have working SNMP support, follow these steps. Click Devices on Cacti's menu. Click Add to add a new device.

Type a description, hostname, management IP, and SNMP community. Make sure to select 'Generic SNMP-enabled Host' under Host Template and click Create. Click Create Graphs for this Host at the top of the page. You should see one or more interfaces listed under the Data Query SNMP - Interface Statistics box. Place a check next to each interface that you want to graph. Below the box, select type of graph that you want to create (bits, bytes, summation, etc).

Click Create, and Create again on the following screen to create your graphs. Normally Cacti (and MRTG) poll every 5 minutes.

If you want to make this more aggressive (make sure you understand what and why you are doing this) you can change the polling service to run as frequently or as infrequently as you wish. My suggestion would be to start with the standard polling interval first. My concern is that you're requesting 30 second resolution. Are you sure you're not looking for real-time monitoring ( )? And are you sure you need it? In two weeks, are you still going to care about 30 second resolution?

Is it going to be worth the hit on bandwidth (and processor cycles) to create the data and to move those bits around? There are techniques available to break it down into a smaller resolution, if you've got that sort of bandwidth/diskspace/pain tolerance. Here's a discussion on discrete resolution polling from 2006: In the past 8 or so years in IT, I've found that if you're trying to do something that no one else has done, you're either on the bleeding edge, or you're doing it wrong. It's up to you to decide where you stand. Cacti is known to allow a 1 minute period data collect, after proper setup described here: Probably a custom setup for a 30 second period is possible, but it is important to take care to CPU consumption on Cacti server, depending on the number of collected data sets.

Native poller spine should be used: Windows monitoring requires SNMP feature to be enabled, and Informant SNMP agent is really recommended to get detailed measures from WMI:. Then the following procedure details how to install graph templates designed for Informant SNMP agent:.